FMCC EUROPE
Components and technical solutions for power electronics

VS50B to VS500B

Utilisation

Electronic sensors to measure d.c., a.c. or pulsating voltages with insulation between primary and secondary circuits..
 



 Vertical+Screen

VS50B

VS125B

VS250B

VS500B
 Nominal primary current

 

 V r.m.s.  

 50

 125

 250

 500

 Measuring range

@±12V (±5%) 

 V peak

 ±75

±187.5 

±375 

 ±750

 Measuring range @±24V (±5%)  V peak

 ±75

 ±187.5

±375

 ±750

 Not measured overload

 10ms/hour

 V peak

 150

 375

 750

 1500

  Max. measuring resistance @ IPMAX & ±15V (±5%) Ω

 67

67 

67 

67 

  Max. measuring resistance @ IPMAX & ±24V (±5%) Ω

 188

 188

188 

188 

  Max. measuring resistance @ IPN & ±24V (±5%) Ω

 0

 0

 0

 0

 Secondary current  at IPN

 

 mA

 50

 50

 50

 50

 Accuracy at UPN

 @+25°C

 %

 ≤±0.9

 ≤ ±0.9

 ≤±0.9

 ≤ ±0.9

 Accuracy at at UPN

-25 ... +70°C

 % 

 ≤±1.5

 ≤±1.5

 ≤±1.5

 ≤±1.5

 Accuracy at at UPN -40 ... +85°C

  % 

 ≤±1.7

 ≤±1.7

 ≤±1.7

 ≤±1.7

 Offset current  @ +25°C & ±24V (±5%)

 mA

 ≤±0.15

 ≤±0.15

 ≤±0.15

 ≤±0.15

 Linearity

0.1UPN ... 1.5UPN

 %

 ≤±0.3

 ≤±0.3

 ≤±0.3

 ≤±0.3

 Delay time (typical)

 

 µs

 ≤10

 ≤10

 ≤10

 ≤10

 di/dt correctly followed

 

 V  / µs

 ≤0.6

 ≤1.5

 ≤3

 ≤6

 Bandwidth

 -3 dB & RM = 50 Ω

 kHz

≤13

≤13 

≤13 

≤13 

 Max. no-load consumption current

 @+24°C (±5%)

 mA

≤50

 ≤50

 ≤50

 ≤50

 Dielectric strength Primary/(Secondary+Screen)

 50 Hz, 1 min

 kV

 3.3

 3.3

 3.3

 3.3

 Dielectric strength Secondary/Screen 

 50 Hz, 1 min

 kV

 0.5

0.5 

0.5 

0.5

Partial discharges :   extinction voltage @10pC, 50Hz

 kV

 ≥1

 ≥1

 ≥1

 ≥1

 Supply voltage

 ±5%

 V d.c.

±12 … ±24 

 ±12 … ±24

  ±12 … ±24

±12 … ±24 

 Mass 

 Kg

 0.450

 0.450

 0.450

 0.450

 Operating temperature

 

 °C

 -40 ... +85

 -40 ... +85

 -40 ... +85

 -40 ... +85

 Storage temperature

 

 °C

 -50 ... +90

 -50 ... +90

 -50 ... +90

 -50 ... +90

  Primary connection

Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100°C

1) UHT+ + UHT- ≤ 4.2 kV peak

and

1)|UHT+ + UHT- |≤ UPMAX
.General data

● Coated electronic circuit.
● Plastic case and insulating resin are self-extinguishing.
● Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M.
●   Protections:
- of the measuring circuit against short-circuits.
- of the measuring circuit against opening. 
- of the power supply against polarity reversal.
● Burn-in test in accordance with FPTC 404304 cycle.
● Tightening torque for M5 terminal studs (N.m): 2 N.m.