Traction Voltage Sensors
Traction current sensors
Electronic technology
 | These voltage sensors use the new ABB 100% electronic technology(the magnetic circuit and Hall probe are no longer required).The voltage to be measured is applied directly to the primary terminals of the sensor.They are specially designed and manufactured to meet the latest Traction standards. |
| Type | Nominal primary voltage (V r.m.s.) | Secondary current at UPN (mA) | Supply voltage (V d.c.) | Secondary connection | Order code | VS50B | 50 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT160050R0001 | VS125B | 125 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT160125R0001 | VS250B | 250 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT160250R0001 | VS500B | 500 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT160500R0001 | VS750B | 750 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT160750R0001 | VS1000B | 1000 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT161000R0001 | VS1500B | 1500 | 50 | ±12 ... ±24 | 4 x M5 studs // 3 x 6,35 x 0,8 Faston | 1SBT161500R0001 | VS2000B | 2000 | 50 | ±12 ... ±24 | 3 x M5 studs | 1SBT162000R0001 | VS3000B | 3000 | 50 | ±12 ... ±24 | 3 x M5 studs | 1SBT163000R0001 | VS4000B | 4000 | 50 | ±12 ... ±24 | 3 x M5 studs | 1SBT164000R0001 | VS4200B | 4200 | 50 | ±12 ... ±24 | 3 x M5 studs | 1SBT164200R0001 |
|
Closed loop Hall effect technology
 | Closed loop Hall effect technology also allows for voltage measurement.For calibrated EM010 sensors, the voltage to be measured is applied directly to the primary terminals of the sensor.On the other hand, for not calibrated EM010 sensors, an external input resistor must be inserted in the primary before connecting the voltage to be measured. |
| Type | Nominal primary voltage (V r.m.s.) | Secondary current at UPN (mA) | Supply voltage (V d.c.) | Secondary connection | Order code | EM010-9239 | 600 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9239 | EM010-9240 | 750 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9240 | EM010-9371 | 1000 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9371 | EM010-9317 | 1500 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9317 | EM010-9318 | 2000 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9318 | EM010-9319 | 3000 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9319 | EM010-9394 | 4200 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9394 | EM010-9354 | 5000 | 50 | ±12 ... ±24 | 5 x M5 studs | EM010-9354 |
Type | Nominal primary voltage (V r.m.s.) | Secondary current at UPN (mA)) | Supply voltage (V d.c.) | Secondary connection | Order code | EM010BBFHP1N | 10 | 50 | ±12 ... ±24 | 3 x M5 studs | EM010BBFHP1N | EM010BEFHP1N | 10 | 50 | ±12 ... ±24 | 3 x 6,35 x 0,8 Faston | EM010BEFHP1N | EM010TENHP1N | 10 | 50 | ±12 ... ±24 | 3 x 6,35 x 0,8 Faston | EM010TENHP1N |
|